China 13.8kV IEEE/ANSI Distribution Transformer Manufacturer
China 13.8kV IEEE/ANSI Distribution Transformer Manufacturer China 13.8kV IEEE/ANSI Distribution Transformer Manufacturer China 13.8kV IEEE/ANSI Distribution Transformer Manufacturer

China 13.8kV IEEE/ANSI Distribution Transformer Manufacturer

Product Description

Product Specifications

  • Capacity: 500–5,000 kVA as a reference selection range; customizable according to project requirements

  • Rated primary voltage: 34.5 kV

  • Rated secondary voltage: 480 V; 480Y/277 V or 480 V delta connection, depending on the load and system design

  • Frequency: 60 Hz for typical North American applications; 50 Hz available subject to design requirements

  • Phase: Three-phase

  • Vector Group: Delta–grounded Wye (Δ–Yg) is a common connection option for 480Y/277 V systems; confirm the connection diagram for the specific project

  • Impedance Voltage: Determined by rated capacity and short-circuit requirements; 5.75% is a documented example for a 5,000 kVA, 34.5 kV to 480 V transformer

 

 

Product Overview

A 34.5kV to 480V Transformer is a medium-voltage step-down power transformer designed to convert 34.5 kV electrical power into a 480 V supply for industrial, commercial, and infrastructure applications. It is commonly used in North American electrical distribution systems to supply switchgear, motor control centers, HVAC equipment, manufacturing machinery, and other low-voltage loads.

Qianchuan offers customized transformer solutions based on project requirements, including rated capacity, voltage ratio, winding connection, impedance voltage, cooling method, insulation level, and tap configuration. Oil-immersed pad-mounted designs are suitable options for outdoor distribution installations where the enclosure, protection, and applicable standards meet site requirements.

Depending on the electrical system, the secondary side can be configured for 480 V three-phase loads or a 480Y/277 V system for both 480 V equipment and 277 V lighting loads. The appropriate winding connection, grounding method, and protection scheme should be determined during engineering design.

When selecting a 34.5kV to 480V step-down transformer, buyers should confirm the required kVA rating, primary grounding arrangement, secondary connection, frequency, impedance, short-circuit withstand capability, installation conditions, and applicable IEEE/ANSI requirements. These details help ensure compatibility with the utility supply and downstream electrical equipment.